CANpro/104-Plus Opto
CANpro/104-Plus Opto PC/104-Plus CAN Controller Connect Tech’s CANpro/104-Plus Opto offers two powerful NXP SJA1000 CAN controllers and 3kV optical isolation to provide maximum protection for your industrial control applications. An extension of Connect Tech’s current CAN controller product line, CANpro/104-Plus Opto is based on a PC/104-Plus bus. The design frees up valuable I/O space offering you greater flexibility within your embedded system. For even more I/O, CANpro/104-Plus Opto includes an 8-bit GPIO header. Dependability, high data rates, network control capabilities and 3kV optical isolation protection make CANpro/104-Plus Opto the ideal choice for industrial control applications that are exposed to harsh conditions or environments.
Xtreme/104-Plus
Xtreme/104-Plus PC/104-Plus Serial Card High performance and versatility are trademarks of the Xtreme/104 PC/104 serial card family. Now the Xtreme/104-Plus offers more choice for your embedded applications requiring a small footprint, but fast data transfer rates. The Xtreme/104-Plus is available with 4 or 8 high speed asynchronous RS-232/422/485 ports, 8 selectable RS-232/422/485/TTL ports, or choose 2 or 4 dedicated RS-423 ports. High performance UARTs provide each port with large data buffering capabilities, and each port on the switchable models can be configured for electrical interface, baud rate, parity, data and stop bits independently. The Xtreme/104-Plus is the perfect combination of flexibility, high performance and cost-effectiveness.
U100P-X3
U100P-X3 Single-channel CAN/CAN FD to USB interface with reinforced galvanic isolation The Kvaser U100P-X3 is a robust, single-channel CAN/CAN FD to USB interface with reinforced galvanic isolation (Tested according EN 60335) that squarely addresses the needs of the evolving automotive development market. Fully compatible with J1939, CANopen, NMEA 2000® and DeviceNet, this is the first in a new range of interfaces that is also suited to rugged applications in marine, industrial, heavy duty vehicle and heavy industries. The Kvaser U100P is also available with 9-pin D-SUB, J1939 or M12 CAN connectors.
U100-X3
U100-X3 Single-channel CAN/CAN FD to USB interface with reinforced galvanic isolation The Kvaser U100-X3 is a robust, galvanically-reinforced (Tested according EN 60335) single-channel CAN/CAN FD to USB interface with a 16-pin OBDII plug. Signal and power isolated, the Kvaser U100 offers enhanced electrical protection, a vibration, shock and drop-proof housing and high-quality cabling that meets the needs of CAN system developers through to service technicians. With an intelligent LED that displays bus loads and error frames, an industry-leading IP67 rating and an innovative connector system, the U100 has numerous stand-out features. Fully compatible with J1939, CANopen, NMEA 2000® and DeviceNet, this suits rugged and higher voltage applications in marine, industrial, construction, heavy-duty, agriculture and automotive, including electric vehicle markets. The Kvaser U100 is also available with 9-pin D-SUB, J1939-13 Type II or M12 CAN connectors.
DIN Rail SE410S-X10
DIN Rail SE410S-X10 Ethernet to CAN/CAN FD interface for DIN Rail mounting Kvaser DIN Rail SE410S-X10 is a powerful Ethernet to CAN/CAN FD interface with support for Kvaser t programs. It has 4 CAN/CAN FD channels, support for I/O via add-on modules and 16GB flash storage. Kvaser DIN Rail SE410S-X10 acts as a master for the add-ons. The housing has a smart mounting clip that attaches to a DIN rail for easy installation. The communication between the I/O modules and the Kvaser DIN Rail SE410S-X10 uses an optical bus, thus there is no need for cables in between. The I/O modules can be controlled either from Kvaser’s CANlib SDK (over Ethernet) or directly on the unit using Kvaser t programs. The Kvaser DIN Rail SE410S-X10 is compatible with applications that use Kvaser’s CANlib SDK.
MACH-ETH
MACH-ETH A flexible interface for Ethernet, CAN(/FD) and LIN bus with user-scripting and I/O The MACH-ETH is an automotive network interface that features one Ethernet port, two CAN FD channels, a LIN channel, a USB and RS-232 port, and multiple I/Os. The device can act as an Ethernet-CAN(/FD) or Ethernet-LIN interface as well as CAN(/FD)-LIN gateway, and a user-scripting feature allows to run user applications directly on the device. The open communication protocol enables access to interface’s channels over Ethernet or USB. The communication protocol over Ethernet or USB enables access to CAN(/FD) and LIN bus channels over Ethernet or virtual COM port respectively. A user-scripting feature, which allows to run user applications directly on the MCU, can be used for HiL testing and rest-bus simulations. The device can act as an interface, a gateway, or bridge between all its channels. An analogue input and a digital output enable the user to interact with external peripherals. Features 10/100 Ethernet port 2 CAN-HS channels with CAN FD support LIN channel USB 2.0 RS-232 Analogue input and digital output 4 DIP switches 10 status LEDs Open communication protocol for integration over Ethernet and USB User-programmable Externally or USB-powered Table-top use or DIN-rail mount Usage Examples ETH-CAN(/FD) and ETH-LIN interface CAN(/FD) — LIN gateway CAN — CAN-FD gateway Remaining bus simulations User-programmable HiL simulations Integration The open communication protocol (API) allows to easily access CAN(/FD) and LIN channels over Ethernet (supports both TCP and UDP) or USB VCP. With the help of the communication protocol, the user can configure the device’s CAN/CAN FD/LIN channels and frames can be transmitted and received. User Programming The device firmware can also be fully customizable in C language. An open-source SDK, which shows the use of all the peripherals, is available on GitHub. A user application can be uploaded into the device over web bootloader or USB. It is also possible to debug the application directly on the target (STM32 SWD). Firmware customizable in C/C++ Free-of-charge C language SDK Free-of-charge IDE and C/C++ compiler Firmware update over USB, Ethernet or ICSP
Show:
Login / Registration
укажите почту
введите пароль
Forgot password?
By clicking «#SUBMIT_NAME»,
you agree to our Privacy Policy
Loading data...
Subscribe to our newsletter
specify your contacts

By clicking «#SUBMIT_NAME»,
you agree to our Privacy Policy

You have successfully subscribed
Now you can receive newsletters