Connect Tech’s CANpro/104-Plus Opto offers two powerful NXP SJA1000 CAN controllers and 3kV optical isolation to provide maximum protection for your industrial control applications.
An extension of Connect Tech’s current CAN controller product line, CANpro/104-Plus Opto is based on a PC/104-Plus bus. The design frees up valuable I/O space offering you greater flexibility within your embedded system. For even more I/O, CANpro/104-Plus Opto includes an 8-bit GPIO header.
Dependability, high data rates, network control capabilities and 3kV optical isolation protection make CANpro/104-Plus Opto the ideal choice for industrial control applications that are exposed to harsh conditions or environments.
Technical specifications | |
Ports | 2 ports |
CAN Controllers | Two CAN 2.0B compliant SJA1000 controller |
I/O Connector Type |
Standard: 2 x 10 pin headers Optional: DB-9 |
GPIO | 8-bit GPIO |
I/O Power Output | 125mA per port |
CAN Controller Clock | 16MHz |
PCI Interface | PLX 9030 |
Optical/Power Isolation | 3kV for each CAN port from the host system |
Decoded Base Address Range |
Each SJA1000 will have a register space of: BasicCAN: Full 32 byte PeliCAN: Full 128 byte |
Dimensions | Fully PCI/104 compliant |
Bus | PC/104-Plus, PCI-104 (PCI) option |
Software Compatibility | Contact us for the most current list |
CAN Transceivers | Support 1.0 Mbps operation and more than 110 nodes on the bus |
Power Requirements | +5V |
Environmental and physical specifications |
|
---|---|
Operating Temperature | -40°C to +85°C (-40°F to +185°F) |
Storage Temperature | -40°C to +125°C (-40°F to +257°F) |
Humidity | 95% non-condensing |
Model | Description |
CRG001 | CANpro/104-Plus Opto, PCI-104 form factor, 2 ports 3kV optical isolation. Pass through PC/104 bus. RoHS Compliant |
CRG001‑01 | CANpro/104-Plus Opto, PCI-104 form factor, 2 ports 3kV optical isolation, DB-9 cables. Pass through PC/104 bus. RoHS Compliant |