Memorator Pro 5xHS
High-performance CAN bus interface and standalone datalogger
Kvaser Memorator Pro 5xHS is a five channel, high performance, CAN (controller area network) bus interface and standalone datalogger that allows users to monitor and collect data from up to five CAN channels using just one device. Standalone mode logs data to an SD card; interface mode connects to the PC via USB. This device supports CAN FD.
Configurable using Kvaser’s Memorator Config Tool, Memorator Professional 5xHS is also capable of running user-developed scripts, written in the Kvaser t programming language. Guidance in creating t programs is supplied.
Ethercan HS
Powerful, real-time Ethernet to CAN interface
The Kvaser Ethercan HS is a powerful, real-time Ethernet to CAN interface that, when linked over the Internet to an Ethernet-equipped PC, allows CAN data to be remotely accessed from anywhere in the world. Built-in Power over Ethernet (PoE) eliminates the need for a separate power cable when you can’t power the device from the CAN bus.
Kvaser’s Ethercan product range makes it easy to implement the Internet of Things (IoT) concept by enabling data from any CAN product or system to be sent over a corporate network or WAN, using the standard Kvaser CANlib API. Users of the Kvaser Ethercan HS can also choose to connect to the device using the built-in REST API for web-enabled devices, such as smartphones.
As a programmable interface, the Kvaser Ethercan HS is suited to advanced applications, such as ECU reflashing. For example, a t program could be created to process CAN messages locally in the device, removing the latency of WiFi and/or Ethernet.
DIN Rail S030-X11 Relay add-on
Optional relay add-on module to the Kvaser DIN Rail SE400S-X10
Kvaser DIN Rail S030-X11 Relay is an optional add-on module to the Kvaser DIN Rail SE400S-X10 base module* with 8 N.O. (Normally Open) relays and 8 digital inputs that can be used separately. This IP20-rated module is thermal, reverse-polarity protected and surge power supply protected. A power LED displays the state of the module, whilst there are separate LEDs for each of the digital inputs.
*Please note: Add-on modules require a Kvaser DIN Rail SE400S-X10 to be able to work.
DIN Rail S020-X10 Analog add-on
Optional analog add-on module to the Kvaser DIN Rail SE400S-X10
Kvaser DIN Rail S020-X10 Analog is an optional add-on module to the Kvaser DIN Rail SE400S-X10 base module*. With 4 analog inputs and 4 outputs, this IP20-rated module is thermal, reverse-polarity protected and surge power supply protected. The input voltage range is fixed (between 0 and 10V), and resolution is 12 bits. A power LED displays the state of the module.
*Please note: Add-on modules require a Kvaser DIN Rail SE400S-X10 to be able to work.
DIN Rail S010-X10 Digital add-on
Optional digital add-on module to the Kvaser DIN Rail SE400S-X10
Kvaser DIN Rail S010-X10 Digital is an optional add-on module to the Kvaser DIN Rail SE400S-X10 base module* with 16 digital inputs and 16 digital outputs. This IP20-rated module is thermal, reverse-polarity protected and surge power supply protected. A power LED displays the state of the module, whilst there are separate LEDs for each of the inputs and outputs.
*Please note: Add-on modules require a Kvaser DIN Rail SE400S-X10 to be able to work.
Hybrid 2xCAN/LIN
USB-2xCAN/LIN interface
Kvaser Hybrid 2xCAN/LIN is a flexible, dual channel interface that allows each channel to be assigned independently as CAN or LIN. This makes the Kvaser Hybrid 2xCAN/LIN a must-have ’universal interface’ for every engineer involved in automotive communications!
With a standard USB connector and two CAN/LIN channels in two separate 9-pin D-SUB connectors, this interface can connect a PC to two CAN buses, two LIN buses, or one CAN and one LIN bus.
Feature List:
Supports High Speed CAN (ISO 11898-2) up to 1Mbit/s and LIN 2.2A (ISO 17987 Part 1-7) up to 20 kbit/s
Capable of sending up to 20000 messages per second, per CAN channel
Supports CAN FD up to 5Mbit/s (with proper physical layer implementation)
Quick and easy plug-and-play installation
Supports CAN 2.0 A and CAN 2.0 B active
USB powered (bus V+ reference required for LIN)
LEDs indicate device status and bus activity
Galvanically isolated CAN buses
Fully compatible with J1939, CANopen, NMEA 2000 and DeviceNet
Supplied with Kvaser CANlib and Kvaser LINlib, free software APIs that are common to all Kvaser hardware and enable the channels to be configured intuitively and fast
Extended operating temperature range from -40 to 85 °C
Support for SocketCAN, see elinux.org for details
Software
Documentation, software and drivers can be downloaded for free at www.kvaser.com/downloads
Kvaser CANLIB SDK is a free resource that includes everything you need to develop software for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Java, Python and Visual Basic
All Kvaser CAN interface boards share a common software API. Programs written for one interface type will run without modifications on the other interface types!
J2534 Application Programming Interface available
RP1210A Application Programming Interface available
USBcan R v2
2-channel CAN bus interface
Kvaser USBcan R v2 is a lightweight, yet highly durable, two channel CAN bus interface. The IP65-rated housing is made of aluminum alloy, sealed with a heavy-duty polyurethane coating that assures reliable protection against water and dust ingress, and is vibration, shock and drop proof.
With a standard USB2.0 connection and two high-speed CAN channels in two separate 9-pin D-SUB CAN connectors, the Kvaser USBcan R v2 handles transmission and reception of standard and extended CAN messages, with a time stamp precision of 100 microseconds. Features include error frame detection and LED indicators showing power and CAN channel status.
Major Features:
Connect to two CAN channels simultaneously using just one device.
IP65 rated lightweight aluminum housing, sealed with polyurethane coating.
Capable of sending up to 15000 messages per second, per channel, each time-stamped with 100 microsecond accuracies.
Quick and easy plug-and-play installation.
Supports High Speed CAN (ISO 11898-2) up to 1Mbit/s.
Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
Power is taken from the USB bus.
Detection of error frames.
LED lights alert user to device status.
100% compatible with applications written for other Kvaser CAN hardware with Kvaser CANlib.
Fully compatible with J1939, CANopen, NMEA 2000 and DeviceNet.
Operating temperature range from −40 to 70°C.
Software
Documentation, software and drivers can be downloaded for free at www.kvaser.com/downloads.
Kvaser CANLIB SDK is a free resource that includes everything you need to develop software for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Java, Python and Visual Basic.
All Kvaser CAN interface boards share a common software API. Programs written for one interface type will run without modifications on the other interface types!
J2534 Application Programming Interface available.
RP1210A Application Programming Interface available.
On-line documentation in Windows HTML-Help and Adobe Acrobat format.
Memorator Pro 2xHS v2
CAN bus interface
Kvaser Memorator Pro 2xHS v2 is a professional-level, dual channel CAN bus interface and standalone data logger offering advanced features such as message filtering, triggers, error detection and generation, silent mode, an expandable SD card slot up to 64G, and galvanic isolation.
Connected to a PC with USB2.0, the Kvaser Memorator Pro 2xHS v2 operates as a powerful real time CAN to USB interface, whilst in data logger mode, the compact design of this device makes for the perfect flight recorder.
Configurable using Kvaser's Memorator Config Tool, this device is capable of running user-developed scripts, written in the Kvaser t programming language. Guidance in creating t programs is provided. The Kvaser Memorator Pro 2xHS v2 is CAN FD compliant.
Major Features:
Monitor two CAN channels simultaneously using just one device.
Log data to an expandable SD card slot.
Supports CAN FD up to 8Mbit/s (with proper physical layer implementation).
Script functionality allows users to develop customised t-script applications written in the Kvaser t programming language.
Power derived from the USB connection, CAN or an in-built power supply.
Supports silent mode for analysis tools – listens to the bus without interfering.
Detection and generation of error frames and remote frames.
LED lights alert user to device status, including signalling a full SD card or card error.
Galvanically isolated CAN bus drivers.
Automatically time synchronises the data transmitted and received across both buses.
Built-in Kvaser MagiSync technology time synchronises with other Kvaser interfaces connected to the same PC, resulting in simpler and more accurate multichannel data capture.
Extended operating temperature range from -40 to 85 °C.
NOTE: Product ships with Commercial Grade SD card (-25 to +85°C). Industrial Grade SD cards (-40 to +85°C) are available for additional purchase. Contact us for details.
Compatible with J1939, CANopen, NMEA 2000® and DeviceNet.
Plug and play installation, and a comprehensive user guide to help make t script development quick and easy.
Software:
Documentation, software and drivers can be downloaded for free at www.kvaser.com/downloads.
Kvaser CANLIB SDK is a free resource that includes everything you need to develop software for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Java, Python and Visual Basic.
All Kvaser CAN interface boards share a common software API. Programs written for one interface type will run without modifications on the other interface types!
J2534 Application Programming Interface available.
RP1210A Application Programming Interface available.
On-line documentation in Windows HTML-Help and Adobe Acrobat format.
D-sub 9 pin 120 Ohm termination adapter
CAN adaptor
Kvaser D-sub 9 pin 120 Ohm termination adapter is a CAN adaptor with a 9-pin male D-Sub connector at one end and a 9-pin female D-Sub socket at the other. Between CAN High (pin 7) and CAN Low (pin 2) there is a built-in 120 Ohm CAN terminating resistor.
This adapter provides quick and easy termination to any Kvaser high-speed CAN product. The Kvaser CAN termination adapter is used when there is a need to terminate a CAN node without internal termination or when no CAN node is connected to the bus. The Kvaser D-sub 9 pin 120 Ohm termination adapter has a 9-pin male D-Sub plug connector and a 9-pin female D-Sub socket. A 120 ohm terminating resistor sits between pins 2 and 7.
T-Cannector v2
CAN bus hub
Kvaser T-cannector v2 is a CAN bus hub with three female and one male D-SUB9 connectors. Used typically in application development scenarios, this offers an adjustable CAN termination resistor (120/60/0 Ohm) that provides an affordable and safe way of terminating the CAN circuit, as well as powering devices that take their power from the USB connection or the CAN network to which they are attached, such as Kvaser’s Blackbird and Memorator series. This device comes with a 12V power supply and EU, USA, UK and Chinese plugs.
Major Features of Kvaser T-cannector v2:
Acts as a CAN bus hub with 3 female and 1 male D-SUB9 connectors
Each DSUB9 has screws to secure the connection to the Kvaser CAN interface
Adjustable termination via easy-to-use switch
12V 1A power supply
LED to indicate power on
Voltage range of 12V-24V DC
This is a new version of an existing product that responds to user requests for more termination options. Notably our previous product came in two versions: with fixed termination of 120 Ohms and without. The Kvaser T-cannector v2 is extremely price-competitive, providing an external 12V 1A power source for Kvaser CAN interfaces and a safe, trustworthy means of circuit termination that protects customer’s interface investment and will prevent short circuits from damaging their development boards.
Loading data...