64-CH 16-Bit 250kS/s Multi-Function DAQ Card.
Features:
Technical specifications | |
Analog Input |
|
---|---|
Number of channels | 64 single-ended or 32 differential (software selectable per channel) |
Resolution | 16 Bit |
Maximum sampling rate | 250 kS/s |
Input signal ranges (software programmable) |
(Gain 1) Bipolar: ±5 V Unipolar: 0 to 10 V (Gain 2) Bipolar: ±2.5 V Unipolar: 0 to 5 V (Gain 4) Bipolar: ±1.25 V Unipolar: 0 to 2.5 V (Gain 8) Bipolar: ±0.625 V Unipolar: 0 to 1.25 V |
Accuracy |
(Gain 1) 0.01% of FSR ± 1 LSB (Gain 2, 4) 0.02% of FSR ± 1 LSB (Gain 8) 0.04% of FSR ± 1 LSB |
Input Coupling | DC |
Overvoltage protection | Continuous ±35 V |
Input Impedance | 1 GΩ |
Trigger modes | Software, pre-trigger, post-trigger, middle trigger, delay trigger, and repeated trigger |
Channel-gain queue size | 512 configurations |
FIFO buffer size | 1 k samples |
Data transfers | polling, interrupt, bus-mastering DMA |
Digital I/O |
|
Number of channels | 8 inputs and 8 outputs |
Resolution | 16 Bit |
Compatibility | 5 V/TTL |
Data transfers | programmed I/O |
General-Purpose timer/counter |
|
Number of channels | 1 |
Resolution | 16 Bit |
Compatibility | 5 V/TTL |
Base clock available | 24 MHz, external clock up to 24 MHz |
General Specifications |
|
I/O connector | 100-pin SCSI-II female |
Power requirements |
+5 V, 560 mA typical +12 V, 100 mA typical |
Dimensions (not including connectors) | 160 mm x 100 mm (6.24" x 3.9") (3U) |
Environmental and physical specifications |
|
Operating temperature | 0˚C to 55˚C (32˚F to 131˚F ) |
Storage temperature | -20˚C to 80˚C (-4˚F to 176˚F) |
Humidity | 5 to 95%, non-condensing |
Model | Description |
cPCI‑9116 | 64-CH 16-Bit 250 kS/s Multi-Function DAQ Module |
DIN‑100S‑01 | Terminal Board with One 100-pin SCSI-II Connector and DIN-Rail Mounting (Cables are not included) |
ACL‑102100‑1 | 100-pin SCSI-II cable (mating AMP-7877082-9), 1M |